  "status": "INCONCLUSIVE PHYSICAL TRANSFER VALIDATION: central predictions meet screening tolerances, but frozen interval fails informativeness",
  "source_title": "Sjokvist and Eriksson 2014 Fig.4 experimental light curve",
  "source_url": "https://uu.diva-portal.org/smash/get/diva2:764071/FULLTEXT01.pdf",
  "printed_page": 4,
  "pdf_page_1_based": 5,
  "figure": 4,
  "outcome_seen_by_builder_before_freeze": false,
  "owner_saw_source_during_selection": true,
  "prediction_sha256": "68d8bfafff97cc4e1f450e3c1f8a5e611c01cf402c6d53cc256a4ea09ffe3067",
  "implementation_sha256": "b427a82d599bbfcb0d7ba97c72122e1ef23af8f8188c34fc5f6cbf38a3fd7f08",
  "protocol_sha256": "b37a29024161996a069abe24eed257687dde9e1d2cd752c87f3f38dbba22c903",
  "extraction_sha256": "4e979d669e48e3e7b915be82cc38c779a351ed41cd3460ddfd5faece040168fb",
  "extraction_method": "Extract PDF vector polyline with mutool draw -F trace; linearly interpolate displayed polyline.",
  "rows": [
    {
      "opposing_DC_ampere_turns": 2000.0,
      "current_DC_A": 4.7281323877068555,
      "measured_delta_B_T": -0.14436791906558155,
      "plot_reading_halfwidth_T": 0.01,
      "predicted_delta_B_T": -0.13873076969281548,
      "absolute_point_error_T": 0.005637149372766076,
      "relative_point_error": 0.039047105542924024,
      "point_tolerance_before_reading_uncertainty_T": 0.02,
      "point_tolerance_total_T": 0.03,
      "point_tolerance_met": true,
      "sensitivity_lower_T": -0.18252840618289817,
      "sensitivity_upper_T": -0.09763784191115686,
      "sensitivity_width_T": 0.08489056427174131,
      "sensitivity_overlaps_observation_interval": true,
      "interval_informativeness_test_applies": false,
      "interval_informativeness_met": null
    },
    {
      "opposing_DC_ampere_turns": 4000.0,
      "current_DC_A": 9.456264775413711,
      "measured_delta_B_T": -0.2958373475271679,
      "plot_reading_halfwidth_T": 0.01,
      "predicted_delta_B_T": -0.27746153938563095,
      "absolute_point_error_T": 0.018375808141536942,
      "relative_point_error": 0.062114564963267255,
      "point_tolerance_before_reading_uncertainty_T": 0.029583734752716792,
      "point_tolerance_total_T": 0.039583734752716794,
      "point_tolerance_met": true,
      "sensitivity_lower_T": -0.36505681236579635,
      "sensitivity_upper_T": -0.19527568382231372,
      "sensitivity_width_T": 0.16978112854348262,
      "sensitivity_overlaps_observation_interval": true,
      "interval_informativeness_test_applies": true,
      "interval_informativeness_met": false
    }
  ],
  "caveats": [
    "Both contrasts share a zero-current observation and are correlated.",
    "Original sensor calibration and full experimental uncertainty are not supplied; 0.010 T is a conservative plot-reading contrast budget only.",
    "Sensitivity bounds were assumed, not calibrated probabilities or guaranteed enclosures.",
    "This is an analytical reluctance-circuit prediction of reversible gap field; no motor FE or local magnet reverse field is validated.",
    "The successful central point checks do not overcome the failed interval-informativeness criterion.",
    "Measured curve values were withheld from the builder; the owner's source selection was not blind or random.",
    "No parameter was retuned after measurement release."
  ]
}